Hotel & ResortDrainage Solutions
Comprehensive drainage systems for hospitality facilities. From pool decks and spas to commercial kitchens and parking structures, solutions that balance functionality, safety, and aesthetic appeal.
Hotel & Resort Drainage Challenges
Hospitality facilities combine diverse drainage needs from pools to kitchens, requiring solutions that prioritize guest safety while maintaining aesthetic appeal.
Multi-Zone Complexity
Hotels combine pools, kitchens, parking, landscaping, and public spaces with vastly different drainage requirements. Each zone needs appropriate products while maintaining cohesive design.
Guest Safety Priority
Guest-facing areas require slip-resistant, heel-safe, ADA-compliant drainage. Barefoot areas around pools need special attention. Aesthetic appearance must not compromise safety.
Aesthetic Integration
Luxury properties demand drainage that complements architectural design. Decorative grates, hidden channels, and premium materials maintain visual appeal in public spaces.
High-Capacity Demands
Large roof areas, pool decks, and parking structures create significant drainage volumes. Systems must handle intense rainfall without flooding guest areas or building interiors.
Hotel & Resort Drainage by Area
Each zone of a hospitality property has specific drainage requirements. Proper zoning ensures guest safety and operational efficiency.
Pool Deck & Spa
Heel-safe grates, slip-resistant, chemical resistant, Class A-B rating
Barefoot guest safety priority. Chlorine and salt resistant materials essential.
Recommended Products:
Commercial Kitchen
NSF certified, stainless steel, grease interceptor connection, high capacity
Banquet kitchens may need multiple drain runs. Health code compliance critical.
Recommended Products:
Parking Structure
Class C-D rating, oil-water separation, heavy-duty grates
Handle vehicle traffic and rainwater intrusion. Environmental compliance required.
Recommended Products:
Porte-Cochere & Entry
Class D rating for vehicles, decorative options, ADA compliant
First impression area. Balance aesthetics with heavy vehicle load capacity.
Recommended Products:
Courtyard & Gardens
Decorative trench drains, catch basins, landscape integration
Hidden or decorative drainage that complements landscape design.
Recommended Products:
Rooftop Amenities
Lightweight options, roof membrane compatible, overflow protection
Weight restrictions may apply. Coordinate with roofing system requirements.
Recommended Products:
Hotel & Resort Drainage Products Compared
Compare drainage products designed for hospitality facilities. Options range from decorative to heavy-duty for various zones.
ShowerDrain
Load Class: A-BPremium stainless steel linear drain system ideal for spa areas, pool showers, and wet rooms. Elegant design with excellent slip resistance for barefoot areas.
Best For:
- Pool shower areas
- Spa wet rooms
- Locker rooms
Considerations:
- Premium pricing
- Excellent aesthetics and durability
Hexaline
Load Class: A-BDecorative linear drain system for courtyards and landscaped areas. Unique hexagonal design complements premium hardscaping and outdoor spaces.
Best For:
- Courtyards
- Garden paths
- Patio areas
Considerations:
- Pedestrian loads only
- Excellent visual integration
PowerDrain S200
Load Class: CHeavy-duty polymer concrete channel for parking structures and vehicle drop-off areas. Class C rating handles guest vehicles and service trucks.
Best For:
- Parking structures
- Porte-cocheres
- Service areas
Considerations:
- Professional installation required
- Decorative grate options available
Stainless Steel Trench
Load Class: B-CNSF-certified stainless steel trench drain for commercial kitchens. Meets health code requirements for hotel food service operations.
Best For:
- Banquet kitchens
- Room service prep
- Main kitchen lines
Considerations:
- Higher cost than polymer
- Industry standard for food service
Slim Channel
Load Class: ALow-profile decorative channel drain for pedestrian areas. Minimal visual footprint with effective drainage for patios and walkways.
Best For:
- Patio thresholds
- Garden walkways
- Pool deck perimeters
Considerations:
- Pedestrian loads only
- Limited flow capacity
Decorative Trench Grates
Load Class: C-DCast iron grates with decorative patterns for high-end applications. Custom patterns available to match architectural themes.
Best For:
- Grand entrances
- Luxury courtyards
- Custom design projects
Considerations:
- Higher cost for custom
- Extended lead time for patterns
| Product Line | Width | Load Class | Material | Heel-Safe | Chemical Resistant | Decorative | Pre-Sloped | NSF Certified | Easy Clean | Low Profile | Decorative Options | Custom Patterns | Made in USA | Best For | Considerations |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2-4" | A-B | Stainless Steel |
|
| |||||||||||
| 4" | A-B | Polymer Concrete |
|
| |||||||||||
| 8" | C | Polymer Concrete |
|
| |||||||||||
| 4-8" | B-C | 304/316 SS |
|
| |||||||||||
| 2.25" | A | Polymer |
|
| |||||||||||
| 6-12" | C-D | Ductile Iron |
|
|
Specifications may vary by model. Consult manufacturer documentation for exact specifications. Load ratings require proper installation with concrete encasement per manufacturer guidelines.
Key Installation Considerations
Hotel drainage requires careful planning across multiple zones. Follow these guidelines for successful hospitality projects.
Guest Safety Standards
All guest-facing drains must meet ADA requirements for heel-safe openings. Pool and spa areas need slip-resistant surfaces. Consider barefoot traffic patterns when selecting grate materials.
Multi-System Coordination
Large hotels require coordinated drainage across multiple zones. Kitchen drains connect to grease interceptors. Parking drains may need oil-water separators. Plan systems holistically.
Aesthetic Consistency
Select products that maintain design consistency across visible areas. Coordinate grate finishes with architectural hardware. Consider custom patterns for signature spaces.
Maintenance Access
Design for easy maintenance without disrupting hotel operations. Kitchen drains need daily cleaning access. Pool drains should be serviceable during off-hours. Include adequate cleanouts.
Load Rating Verification
Verify load ratings match actual traffic. Porte-cocheres see heavy trucks. Pool decks see pedestrians only. Parking structures need vehicle ratings. Match products to zone requirements.
Health Department Compliance
Kitchen and food service areas require health department approval. NSF-certified drains and proper grease interceptor sizing are mandatory. Document installations for inspections.
Explore Product Lines for Hospitality Drainage
Hotel & Resort Drainage FAQ
Common questions about drainage systems for hospitality facilities.
Hotel pool decks require slip-resistant drainage with heel-safe grates for barefoot guests. Trench drains around the pool perimeter capture splash-out and rainwater. Class A-B rated drains handle pedestrian traffic. Stainless steel or polymer options resist chlorine and pool chemicals.
Hotel commercial kitchens require NSF-certified stainless steel floor drains and trench drains connected to grease interceptors. High-volume banquet kitchens need larger capacity systems. All drains must be easily cleaned and maintained. Pre-sloped channels like NDS Dura Slope ensure proper drainage.
Hotel parking garages need Class C-D rated trench drains to handle vehicle traffic and capture rainwater driven in by vehicles. Oil-water separators may be required for environmental compliance. Stainless steel or ductile iron grates withstand constant vehicle loads.
Hotel courtyards require decorative drainage options that complement the landscape design. ACO Hexaline and similar decorative trench drains blend with pavers and hardscaping. Catch basins can be fitted with decorative grates. Drainage should be hidden but functional.
Spa areas need slip-resistant drainage with excellent chemical resistance for chlorine, salt, and treatment chemicals. Stainless steel linear drains are popular for wet rooms and shower areas. All drains should be ADA compliant and heel-safe for barefoot guests.
Hotel entrances require heavy-duty trench drains rated Class D or higher for vehicle traffic at drop-off areas. Decorative grate options maintain aesthetic appeal while handling rainwater. ADA-compliant, heel-safe designs protect guests with luggage and mobility devices.
Hotel laundries need high-capacity floor drains to handle discharge from commercial washing machines. Chemical-resistant materials withstand detergents and cleaning agents. Lint interceptors may be required. Floor slopes should direct water toward drains efficiently.
Rooftop pools, bars, and event spaces need drainage designed for the specific roof assembly. Weight considerations affect product selection. Overflow drains and scuppers supplement primary drainage. Waterproofing integration is critical for below-space protection.
Planning a Hospitality Drainage Project?
Get expert guidance on drainage systems for hotels, resorts, and hospitality facilities of all sizes.