Commercial KitchenDrainage Solutions
PDI-certified grease interceptors, NSF floor drains, and stainless steel trench systems for restaurants, hotels, hospitals, and institutional kitchens. Complete grease management solutions that meet health code requirements.
Commercial Kitchen Drainage Challenges
Commercial kitchens face unique drainage challenges including grease management, high-temperature discharge, and strict health code compliance requirements.
Grease Management
Fats, oils, and grease (FOG) accumulate in drainage systems, causing blockages and sewer overflows. Proper grease interceptors and regular maintenance are mandated by most jurisdictions to protect municipal sewer systems.
High-Temperature Discharge
Dishwashers, steam equipment, and pot wash operations discharge water at 140-180°F. Drainage components must handle thermal shock without damage, and grease interceptors require temperature management to function properly.
Health Code Compliance
Health departments inspect kitchen drainage for proper equipment connections, air gaps, trap maintenance, and grease interceptor condition. Non-compliance can result in closure orders and fines.
Food Waste Handling
Solid food particles must be captured before entering the drainage system. Floor drains, floor sinks, and trench drains require basket strainers. Garbage disposals add to drainage load and affect interceptor sizing.
Industry Standards & Compliance
Commercial kitchen drainage must comply with multiple standards and local regulations.
PDI G101
Sizing and testing standard for hydromechanical grease interceptors. Specifies flow rate, grease retention, and performance testing requirements.
NSF/ANSI 18
Standard for manual food and beverage dispensing equipment. Applies to floor drains, floor sinks, and related drainage components in food service.
Local FOG Ordinances
Many municipalities have Fats, Oils, and Grease (FOG) programs with specific interceptor and maintenance requirements. Always verify local regulations.
Health Codes
State and local health departments enforce drainage requirements during inspections. Requirements vary but focus on cleanability, air gaps, and grease control.
Commercial Kitchen Drainage by Area
Each area of a commercial kitchen has specific drainage requirements based on grease load, water volume, and equipment connections.
Cooking Line
Floor drains with sediment baskets, grease interceptor connection, heat-resistant, heel-proof grates
High heat exposure. Position drains for equipment washdown collection.
Recommended Products:
Dish Room
High-capacity drainage, floor sinks for air gaps, pre-rinse sink drains, trench optional
Highest water volume area. Check code for dishwasher-interceptor requirements.
Recommended Products:
Pot Wash Area
3-comp sink floor sinks, grease connection, sediment capture, heavy-duty grates
Major grease source. Size floor sinks for simultaneous drain-down.
Recommended Products:
Prep Area
Floor drains for cleaning, food waste capture, ADA-compliant grates, NSF certified
Moderate drainage needs. Focus on cleanability and food waste capture.
Recommended Products:
Walk-In Cooler/Freezer
Freeze-resistant drains (freezer), defrost drainage, deep seal traps, no grease connection
Special thermal requirements. Freezer drains need electric heat trace.
Recommended Products:
Bar/Beverage Area
Bar sinks, glass rinser drains, floor sinks, aesthetic options for exposed areas
Customer visibility may affect product selection. No grease interceptor typically required.
Recommended Products:
Commercial Kitchen Drainage Products Compared
Compare grease interceptors, floor drains, and trench systems for commercial kitchen applications. All products meet NSF and PDI certification requirements.
Grease Interceptors
Load Class: N/APDI G101-certified hydromechanical grease interceptors in various sizes. Compact design for under-sink or indoor installation. Removable baffles for easy cleaning.
Best For:
- Point-of-use installation
- Limited space situations
- Single fixture connections
Considerations:
- Frequent cleaning required
- Size for fixture flow
Lipumax Grease Separator
Load Class: N/AHigh-capacity grease separation system for commercial kitchens. Stainless steel construction with automatic grease removal option. Designed for continuous operation.
Best For:
- High-volume kitchens
- Grease-heavy operations
- Reduced maintenance goals
Considerations:
- Higher upfront cost
- Professional installation
Stainless Floor Drains
Load Class: B-CNSF-certified stainless steel floor drains designed for commercial kitchens. Deep seal traps, removable sediment baskets, and multiple grate options. Industry standard for food service.
Best For:
- Cooking line drainage
- General kitchen floors
- Equipment positions
Considerations:
- Size for peak washdown
- Specify grate type
Stainless Floor Sinks
Load Class: A-BHeavy-duty floor sinks for indirect waste connections. Essential for 3-compartment sinks, dishwashers, and equipment air gaps. NSF-certified with various strainer options.
Best For:
- 3-comp sink discharge
- Equipment air gaps
- Dishwasher drains
Considerations:
- Daily strainer cleaning
- Size for fixture flow
Kitchen Trench Drain
Load Class: B-CNSF-certified stainless steel trench systems for commercial kitchens. Pre-sloped options available. Heel-proof grates meet ADA requirements. Connects to grease interceptor systems.
Best For:
- Cooking line runs
- Dish room perimeters
- High-volume areas
Considerations:
- Heel-proof grates required
- Include cleanouts
Dura Slope Stainless
Load Class: B-CPre-sloped HDPE channel with stainless steel grate options. Cost-effective solution for kitchen applications where full stainless construction isn't required. Easy installation.
Best For:
- Value-conscious projects
- Service corridors
- Storage areas
Considerations:
- Verify temperature rating
- Not for heavy grease areas
Floor Drain Accessories
Load Class: N/ATrap primers, trap guards, and drain accessories for commercial kitchen applications. Maintain trap seals in low-use drains. Prevent sewer gas entry and pest access.
Best For:
- Floor drain maintenance
- Low-use drain locations
- Sewer gas prevention
Considerations:
- Requires water supply
- Install per code
| Product Line | Flow Rate | Grease Capacity | Material | PDI Certified | Flow Control | Auto Option | Sizes | Trap Seal | NSF Certified | Sediment Basket | Depth | Strainer Options | Width | Load Class | Pre-Sloped | Chemical Resistant | Type | Connection | Automatic | Low Flow | Best For | Considerations |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 10-100 GPM | 8-70 lb | Cast Iron/SS |
|
| ||||||||||||||||||
| 15-100 GPM | 20-80 lb | 304 SS |
|
| ||||||||||||||||||
| 304 SS | 6-12" dia | 4" deep |
|
| ||||||||||||||||||
| 304 SS | 8-14" sq | 6-12" |
|
| ||||||||||||||||||
| 304 SS | 4-8" | B-C |
|
| ||||||||||||||||||
| HDPE/SS Grate | 6" | B-C |
|
| ||||||||||||||||||
| Brass/SS | Trap Primer | 1/2" supply |
|
|
Specifications may vary by model. Consult manufacturer documentation for exact specifications. Load ratings require proper installation with concrete encasement per manufacturer guidelines.
Key Installation Considerations
Proper drainage design is critical for health code compliance and efficient kitchen operations. Follow these guidelines for successful installations.
Grease Interceptor Sizing
Size interceptors per PDI G101 or local code. Calculate total fixture flow rates, apply retention time, and select appropriate capacity. Consult local authorities as requirements vary significantly by jurisdiction.
Air Gap Requirements
Plumbing codes require air gaps between food equipment discharge and floor drains/sinks. This prevents cross-contamination from drain backup. Floor sinks provide air gap connections for sinks, dishwashers, and other equipment.
Floor Slope Design
Design floors with 1/8" to 1/4" per foot slope toward drains. Quarry tile, sealed concrete, or epoxy floors are standard. Ensure slip-resistant surfaces even when wet. Cove base transitions prevent moisture intrusion.
Drain Placement
Position floor drains at equipment washdown points and low areas. Space drains 10-15 feet apart maximum in production areas. Include trench drains along cooking lines and dish room perimeters.
Hot Water Management
Dishwasher and hot water discharge can disrupt grease interceptor operation. Some codes require tempering or separate drainage for hot water fixtures. Verify local requirements for dishwasher connections.
Maintenance Access
Design for easy interceptor access for pumping and inspection. Include cleanouts in trench drains every 20-25 feet. Floor drain baskets must be easily removable for daily cleaning. Document maintenance for health inspections.
Explore Product Lines for Commercial Kitchens
Commercial Kitchen Drainage FAQ
Common questions about drainage systems, grease interceptors, and floor drains for commercial kitchens.
Grease interceptor sizing is based on fixture drainage flow rate and local code requirements. Most jurisdictions follow the PDI (Plumbing and Drainage Institute) sizing formula or UPC/IPC code calculations. Factors include number of fixtures draining to the interceptor, flow rates, and retention time. A typical restaurant might need a 50-100 GPM interceptor. Consult local authorities and PDI G101 for proper sizing.
Grease traps (also called hydromechanical grease interceptors) are smaller, typically 10-100 GPM, installed inside or near the kitchen. They require frequent cleaning (often weekly). Grease interceptors (gravity grease interceptors) are larger, buried outside, and are pumped less frequently (monthly to quarterly). Many codes distinguish between them by capacity or retention time.
Kitchen cooking areas typically require NSF-certified stainless steel floor drains with deep seal traps (4" minimum), sediment baskets, and grease-handling capacity. Drains must connect to a grease interceptor in most jurisdictions. Heel-proof, ADA-compliant grates are standard. Size floor drains for expected washdown volume - typically 6" to 12" diameter.
This varies by jurisdiction. Many codes exempt dishwashers from grease interceptor requirements because the hot water and detergent can emulsify grease and potentially disrupt interceptor operation. Check local regulations. Where required, dishwashers may drain to a separate interceptor or require temperature management. Always verify with local plumbing authority.
3-compartment sinks require indirect drainage via an air gap to a floor sink or floor drain. The floor sink must connect to the grease interceptor. Size the floor sink for the sink discharge volume. Include basket strainers to capture food solids. Position floor sinks close to the 3-compartment sink to minimize floor piping.
Cleaning frequency depends on interceptor size, kitchen volume, and local regulations. Most jurisdictions require pumping when grease and solids reach 25% of capacity. Typical schedules range from weekly (small traps) to quarterly (large outdoor interceptors). Maintain cleaning records for health department inspections. Some areas require specific pumping intervals regardless of capacity.
AGRDs are mechanical devices that automatically skim and collect grease from the interceptor, typically storing it in a separate container. They maintain interceptor efficiency by preventing grease accumulation. AGRDs can reduce pumping costs but require regular collection of skimmed grease. They must be PDI-certified where required.
Commercial kitchen trench drains should be stainless steel (304 minimum), NSF-certified, and sized for washdown volumes. Pre-sloped channels ensure positive drainage. Grates must be heel-proof (max 1/4" openings) and handle expected traffic. Connect to grease interceptors. Common widths are 4" to 8". Include cleanouts every 20-25 feet.
Walk-in coolers need floor drains for defrost water and cleaning. Use freeze-resistant designs with heating elements in freezer areas. Deep seal traps prevent odor issues. Drains may need to bypass grease interceptors since cooler drainage doesn't typically contain grease. Check local codes for cooler-specific requirements.
Commercial kitchen floors should slope 1/8" to 1/4" per foot toward floor drains. Steeper slopes (up to 1/4" per foot) in high-volume areas like dish rooms and pot wash. Floors must be slip-resistant even when wet. Quarry tile, sealed concrete, or epoxy coatings are common. Proper slope prevents standing water that creates slip hazards and bacterial growth.
Planning a Commercial Kitchen Project?
Get expert guidance on grease interceptors, floor drains, and drainage systems for your restaurant, hotel, or institutional kitchen.